Flame Monitoring Is Applied to Industrial Kilns and Heating Furnaces.

  • Audited Supplier
  • 3 yrs

Contact Supplier

Product Highlights

  • High Precision Detection: Detects specific UV wavelengths to accurately determine flame state and subtle changes.
  • Fast Response Speed: Integrated detector responds in milliseconds, tracking flame ignition and extinction instantly.
  • Strong Anti-Interference: Insensitive to visible light and high-temperature radiation, eliminating false alarms.
  • Durable Aluminum Housing: Encapsulated design provides dust, water resistance, and anti-electromagnetic interference.
  • Active Cooling System: Front-end air-cooled pipe protects internal components from high furnace temperatures.
  • ISO Certified Quality: Manufacturing process certified under ISO9001, ISO14001, and ISO45001 standards.
  • 12-Month Warranty: Comprehensive warranty coverage for 12 months with online support available.
  • Flexible Customization: Offers full, minor, and sample-based customization with OEM/ODM services.

Product Images of Flame Monitoring Is Applied to Industrial Kilns and Heating Furnaces.

Flame Monitoring Is Applied to Industrial Kilns and Heating Furnaces.
Flame Monitoring Is Applied to Industrial Kilns and Heating Furnaces. pictures & photos
Flame Monitoring Is Applied to Industrial Kilns and Heating Furnaces.
Flame Monitoring Is Applied to Industrial Kilns and Heating Furnaces. pictures & photos
Flame Monitoring Is Applied to Industrial Kilns and Heating Furnaces.
Flame Monitoring Is Applied to Industrial Kilns and Heating Furnaces. pictures & photos
Flame Monitoring Is Applied to Industrial Kilns and Heating Furnaces.
Flame Monitoring Is Applied to Industrial Kilns and Heating Furnaces. pictures & photos
Flame Monitoring Is Applied to Industrial Kilns and Heating Furnaces.
Flame Monitoring Is Applied to Industrial Kilns and Heating Furnaces. pictures & photos
Flame Monitoring Is Applied to Industrial Kilns and Heating Furnaces.
Flame Monitoring Is Applied to Industrial Kilns and Heating Furnaces. pictures & photos
Flame Monitoring Is Applied to Industrial Kilns and Heating Furnaces.
  • Flame Monitoring Is Applied to Industrial Kilns and Heating Furnaces.
  • Flame Monitoring Is Applied to Industrial Kilns and Heating Furnaces.
    Flame Monitoring Is Applied to Industrial Kilns and Heating Furnaces.
  • Flame Monitoring Is Applied to Industrial Kilns and Heating Furnaces.
    Flame Monitoring Is Applied to Industrial Kilns and Heating Furnaces.
  • Flame Monitoring Is Applied to Industrial Kilns and Heating Furnaces.
    Flame Monitoring Is Applied to Industrial Kilns and Heating Furnaces.
  • Flame Monitoring Is Applied to Industrial Kilns and Heating Furnaces.
    Flame Monitoring Is Applied to Industrial Kilns and Heating Furnaces.
  • Flame Monitoring Is Applied to Industrial Kilns and Heating Furnaces.
    Flame Monitoring Is Applied to Industrial Kilns and Heating Furnaces.
  • Flame Monitoring Is Applied to Industrial Kilns and Heating Furnaces.
    Flame Monitoring Is Applied to Industrial Kilns and Heating Furnaces.

Find Similar Products

Product Description

Scope of application

Mainly used for flame monitoring of gas - fired and oil - fired industrial burners and industrial kilns. It is widely applied in industries such as petroleum, chemical engineering, metallurgy

       
 

How it works

Flame Monitoring Is Applied to Industrial Kilns and Heating Furnaces.
 Usually, an ultraviolet phototube that responds to the narrow ultraviolet band of 185 - 260nm is adopted. When the specific ultraviolet rays generated by the flame irradiate the ultraviolet phototube, it will trigger the photoelectric effect and generate an electrical signal. After being amplified and processed, this signal can be used to determine the presence or absence of the flame and the intensity information. Some integrated ultraviolet flame detectors will also cooperate with the identification of the characteristic flicker frequency of the flame to detect the flame more accurately.
 
Flame Monitoring Is Applied to Industrial Kilns and Heating Furnaces.
Structural features: Generally, the ultraviolet probe and the detection control mainboard are integrated and encapsulated in a single housing. To address protection issues such as dust and water resistance, and to enhance anti-electromagnetic interference performance, the housing is mostly made of aluminum alloy. In addition, an air-cooled pipe is usually installed at the front end for introducing cooling air, which cools down the internal key components and prevents equipment damage caused by factors such as high temperature in the furnace chamber.
 
 
 
Flame Monitoring Is Applied to Industrial Kilns and Heating Furnaces.
Strong anti-interference capability: It is only sensitive to ultraviolet rays generated by flames and does not respond to light, high-temperature radiation in the furnace chamber, etc., which can effectively eliminate interference from these factors. For example, in an industrial kiln environment, it can avoid false alarms caused by high temperatures in the furnace chamber.

 

Technical features

Flame Monitoring Is Applied to Industrial Kilns and Heating Furnaces.
 Fast response speed: Since the generation and disappearance of ultraviolet rays are almost synchronous with the ignition and extinguishing of flames, the integrated ultraviolet flame detector can quickly detect flame changes, with a response time usually reaching the millisecond level. For example, the response speed of the Rosemount 975UF ultra-fast ultraviolet and infrared flame detector is less than 20 milliseconds.
 
 
 
Flame Monitoring Is Applied to Industrial Kilns and Heating Furnaces.
High detection accuracy: By detecting ultraviolet rays of specific wavelengths, it can accurately determine the state of the flame and promptly detect subtle changes in the flame, providing reliable guarantee for the stable operation of the combustion system.
 

 

Flame Monitoring Is Applied to Industrial Kilns and Heating Furnaces.
 

Installation and maintenance: During installation, ensure that the probe is aligned with the flame, and the target flame should fill the probe's viewing angle as much as possible. Meanwhile, the detection channel in front of the probe must be ventilated and cooled to prevent damage to the sensor caused by high-temperature conduction from the furnace chamber. The cooling air is required to be dry and clean. In terms of maintenance, some products are equipped with an automatic self-inspection function to ensure that the equipment remains in a stable working state continuously.

 

Company Profile

 

 
 
 
 
 
 
 
 
 
Flame Monitoring Is Applied to Industrial Kilns and Heating Furnaces.
Address: Huji Industrial Park, Deshang Expressway, Mudan District, Heze City, Shandong Province, China
Business type: Manufacturer/factory, trading company
Business scope: manufacturing and processing machinery
Management system certification: ISO9001:2015 ISO45001:2018 ISO14001:2015
Main products: Ground flare, Biogas flares, flare stack,
Thermal Oxidation Furnace, Flue gas purification equipment
Flame Monitoring Is Applied to Industrial Kilns and Heating Furnaces.
Heze Zexuan Equipment Manufacturing Co., Ltd. is an enterprise engaged in the manufacture of special equipment for environmental protection; sales of special equipment for environmental protection; application of industrial automation technology; sales of power electronic components; research and development of mechanical equipment; sales of intelligent instruments and meters; manufacturing of intelligent instruments and meters; research and development and promotion of comprehensive utilization of waste gas and VOCs treatment technology.
The company's main products and service directions: manufacturing of ground torches, elevated torches, waste gas venting torches, biogas torches, three waste incinerators, and wastewater treatment equipment, industrial automation and DCS system applications, wastewater treatment projects, VOCs treatment equipment and engineering construction, petrochemical accessories and instrument sales, petrochemical equipment installation, maintenance and repair, etc.; support product customization services and OEM services in the same industry, from design to manufacturing, installation, commissioning, and after-sales one-stop service.
 

Certifications

Flame Monitoring Is Applied to Industrial Kilns and Heating Furnaces.
Flame Monitoring Is Applied to Industrial Kilns and Heating Furnaces.
Flame Monitoring Is Applied to Industrial Kilns and Heating Furnaces.
 
 
 
 
 
 
 
 

About the Supplier

This supplier has been audited by BV. Verify the report on the official BV website with ID "MIC-ASR265798". Items marked "verified" are certified.

Watch Video
Watch Video
Heze Zexuan Equipment Manufacturing Co., Ltd.
Heze Zexuan Equipment Manufacturing Co., Ltd.
Heze Zexuan Equipment Manufacturing Co., Ltd.
Heze Zexuan Equipment Manufacturing Co., Ltd.
Heze Zexuan Equipment Manufacturing Co., Ltd.
Heze Zexuan Equipment Manufacturing Co., Ltd.
Heze Zexuan Equipment Manufacturing Co., Ltd.
Heze Zexuan Equipment Manufacturing Co., Ltd.

About Our Factory & Business Background

verified Business Type
Manufacturer/Factory & Trading Company
Address
Heze, Shandong, China
verified Plant Area
24179 square meters
verified Number of Employees
34
verified Registered Capital
3,000,000 RMB
verified Terms of Payment
LC, T/T, D/P, PayPal, Western Union, Small-amount payment
verified International Commercial Terms(Incoterms)
FOB, CIF, CFR, EXW
verified Average Lead Time
Peak Season Lead Time: one month, 1-3 months
Off Season Lead Time: one month, 1-3 months
verified Nearest Port
Qingdao Port
verified Minimum Order Quantity
1
verified Supply Chain Partners
50

Our Production Capability & Technical Expertise

verified Main Products
Biogas Flare, Ground Flare, Flare Stack, Flue Gas Purification Equipment, Thermal Oxidation Furnace, VOCs Waste Gas Treatment, Wastewater Treatment, Industrial Automation and DCS System Application
verified Production Lines
2
verified Production Machines
Laser cutting machine, Bending machine, Submerged arc welding machine
verified QA/QC inspectors
2 people
verified Inspection Type for Finished Products
100% inspection(Visual inspection & Function inspection)
verified Inspection Method for Finished Products
Have instructions and uniformly followed
verified Customization Options
Customization from Samples, Customization from Designs, Full Customization, Minor Customization, Flexible customization
verified ODM Service Available
Yes
verified OEM Service Available
Yes
verified R&D Engineers
6 people
verified Traceability of Raw Materials
Yes
verified Test Reports for Raw Materials
Others

Our Industry Experience & Global Business Record

verified Year of Establishment
2019-12-20
verified Export Year
3 years
verified Main Markets
Domestic, Asia
verified Repeat Buyers Choice
50%~80%
verified Number of Foreign Trading Staff
3
verified Overseas Agent/Branch
No
verified New Products Launched in Last year
Yes

Our Certifications, Standards & Industry Recognition

verified Management System Certification
ISO9001:2015, ISO45001:2018, ISO14001
verified Cooperated with Fortune 500
No

FAQ

What industries use this flame monitoring instrument?
It is mainly used in petroleum, chemical engineering, and metallurgy industries for gas and oil-fired burners and industrial kilns.
How does the detector work?
It uses an ultraviolet phototube to detect UV rays (185-260nm) from the flame, triggering a photoelectric effect to generate an electrical signal for flame presence and intensity.
Is the response time fast enough for safety?
Yes, the response time reaches the millisecond level, allowing for quick detection of flame changes almost synchronous with ignition.
Does it prevent false alarms from heat?
Yes, it is only sensitive to UV rays from flames and does not respond to high-temperature radiation or light in the furnace chamber.
What is the warranty period?
The product comes with a 12-month warranty and includes online support for after-sales service.
Can the product be customized?
Yes, we offer full customization, minor customization, and customization from samples or designs, including OEM and ODM services.
What are the minimum order requirements?
The minimum order quantity is 1 set.
What are the payment terms?
We accept LC, T/T, D/P, PayPal, Western Union, and small-amount payments.

Send your message to this supplier

Contact Information
Recipient
Message

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now